600V/1000V XLPE Insulated Galvanized Steel Tape Armored Cable with Lead Cover to IEC 60502-1

Application

These cables are used for electricity supply in low voltage installation system. They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where require hydrocarbon and mechanical protections. The sheath brings an enhanced resistance to aliphatic and aromatic hydrocarbon.

Cable Construction

images/600V/1000V XLPE Insulated Galvanized Steel Tape Armored Cable with Lead Cover to IEC 60502-1.jpg

Construction

Conductor Solid or stranded copper
Insulation XLPE
Core identification 1 Core: Red or Black
2 Cores: Red, Black
3 Cores: Red, Yellow, Blue
4 Cores: Red, Yellow, Blue, Black
5 Cores: Red, Yellow, Blue, Black, Green
Above 5 cores: Black core printed with white numbers
Inner sheath PVC
Lead cover  
Bedding Paraffin-waxed crepe paper
Armor Galvanized steel tapes or aluminum tapes for 1 core cable
Sheath Special PVC. Color: black

Properties

Rated voltage 600V/1000V
Fire retardance IEC 60332-3-22
Operating temperature -20~60°C
Max. conductor operating temperature 90°C
Chemical resistance Aliphatic and aromatic hydrocarbon resistance
No. of Cores Conductor Diameter over Insulation Diameter over Inner Sheath Diameter over Lead Sheath Diameter over Armor Min. O.D. Max. O.D. Approx.Weight
Corss-section (mm2) Type (mm) (mm) (mm) (mm) (mm) (mm) (kg/km)
1 25 Stranded, Class 2 7.9 9.9 12.3 15.8 18.8 20.8 1003
1 35 Stranded, Class 2 8.9 10.9 13.3 16.8 19.79 21.8 1155
1 50 Stranded, Class 2 10.2 12.2 14.6 18.1 21.05 23.2 1341
1 70 Stranded, Class 2 12.0 14.0 16.4 19.9 22.8 25.2 1639
1 95 Stranded, Class 2 13.55 15.6 18.0 21.5 24.35 26.9 1966
1 120 Stranded, Class 2 15.26 17.3 19.9 23.4 26.19 28.9 2371
1 150 Stranded, Class 2 16.97 19.0 21.6 25.1 27.84 30.7 2736
1 185 Stranded, Class 2 19.05 21.0 23.8 27.4 30.07 33.2 3305
1 240 Stranded, Class 2 21.6 23.6 26.6 30.1 32.88 36.3 4115
1 300 Stranded, Class 2 24.2 26.2 29.2 32.7 35.6 39.3 4882
1 400 Stranded, Class 2 27.7 30.1 33.3 36.8 39.77 43.9 6108
1 500 Stranded, Class 2 31.4 33.8 37.2 40.7 43.94 48.5 7570
1 630 Stranded, Class 2 36.2 38.6 42.2 45.7 48.98 54.0 9461
2 1.5 Solid, Class 1 2.79 7.9 10.3 12.4 15.52 17.1 701
2 1.5 Stranded, Class 2 2.9 8.2 10.6 12.7 15.81 17.4 727
2 2.5 Solid, Class 1 3.15 8.6 11.0 13.1 16.2 17.9 773
2 2.5 Stranded, Class 2 3.31 9.1 11.5 13.6 16.68 18.4 813
2 4 Solid, Class 1 3.61 9.5 11.9 14.0 17.07 18.8 871
2 4 Stranded, Class 2 3.83 10.2 12.6 14.7 17.75 19.6 928
2 6 Stranded, Class 2 4.35 11.0 13.4 15.5 18.53 20.4 1022
2 10 Stranded, Class 2 5.25 12.8 15.2 17.3 20.27 22.4 1234
2 16 Stranded, Class 2 6.25 14.8 17.2 19.3 22.21 24.5 1508
2 25 Stranded, Class 2 7.9 18.1 20.5 22.6 25.41 28.0 1980
2 35 Stranded, Class 2 8.9 20.1 22.5 24.6 27.35 30.2 2341
2 50 Stranded, Class 2 10.2 22.8 25.4 27.5 30.17 33.3 2924
2 70 Stranded, Class 2 12.0 26.4 29.2 31.3 34.24 37.8 3809
2 95 Stranded, Class 2 13.55 29.9 32.9 36.4 39.38 43.4 5202
2 120 Stranded, Class 2 15.26 33.3 36.5 40.0 43.07 47.5 6258
2 150 Stranded, Class 2 16.97 36.7 40.1 43.7 47.04 51.9 7450
2 185 Stranded, Class 2 19.05 41.3 44.9 48.4 51.8 57.1 9051
2 240 Stranded, Class 2 21.6 46.4 50.4 53.9 57.52 63.4 11373
2 300 Stranded, Class 2 24.2 52.0 56.2 59.7 63.54 70.1 13803
3 1.5 Solid, Class 1 2.79 8.3 10.7 12.9 16.0 17.7 745
3 1.5 Stranded, Class 2 2.9 8.7 11.1 13.2 16.3 18.0 772
3 2.5 Solid, Class 1 3.15 9.1 11.5 13.6 16.68 18.4 826
3 2.5 Stranded, Class 2 3.31 9.6 12.0 14.2 17.27 19.0 870
3 4 Solid, Class 1 3.61 10.1 12.5 14.6 17.65 19.5 942
3 4 Stranded, Class 2 3.83 10.8 13.2 15.4 18.43 20.3 1003
3 6 Stranded, Class 2 4.35 11.7 14.1 16.2 19.21 21.2 1111
3 10 Stranded, Class 2 5.25 13.6 16.0 18.2 21.15 23.3 1369
3 16 Stranded, Class 2 6.25 15.8 18.2 20.3 23.18 25.6 1700
3 25 Stranded, Class 2 7.9 19.4 21.8 23.9 26.68 29.4 2263
3 35 Stranded, Class 2 8.9 21.5 24.1 26.2 28.91 31.9 2800
3 50 Stranded, Class 2 10.2 24.4 27.2 29.4 32.2 35.5 3528
3 70 Stranded, Class 2 12.0 28.7 31.7 33.8 36.67 40.4 4658
3 95 Stranded, Class 2 13.55 32.1 35.3 38.8 41.9 46.2 6288
3 120 Stranded, Class 2 15.26 35.8 39.2 42.7 45.88 50.6 7585
3 150 Stranded, Class 2 16.97 39.9 43.5 47.0 50.44 55.6 9123
3 185 Stranded, Class 2 19.05 44.4 48.2 51.7 55.19 60.9 11013
3 240 Stranded, Class 2 21.6 50.3 54.5 58.0 61.69 68.0 13976
3 300 Stranded, Class 2 24.2 55.9 60.3 63.8 67.71 74.7 16888
4 1.5 Solid, Class 1 2.79 9.0 11.4 13.6 16.68 18.4 809
4 1.5 Stranded, Class 2 2.9 9.4 11.8 14.0 17.07 18.8 841
4 2.5 Solid, Class 1 3.15 9.9 12.3 14.4 17.46 19.3 906
4 2.5 Stranded, Class 2 3.31 10.5 12.9 15.1 18.14 20.0 950
4 4 Solid, Class 1 3.61 11.0 13.4 15.6 18.62 20.5 1041
4 4 Stranded, Class 2 3.83 11.9 14.3 16.4 19.4 21.4 1103
4 6 Stranded, Class 2 4.35 12.8 15.2 17.4 20.37 22.5 1242
4 10 Stranded, Class 2 5.25 15.0 17.4 19.5 22.41 24.7 1558
4 16 Stranded, Class 2 6.25 17.4 19.8 22.0 24.83 27.4 1972
4 25 Stranded, Class 2 7.9 21.4 24.0 26.1 28.81 31.8 2734
4 35 Stranded, Class 2 8.9 23.9 26.5 28.7 31.52 34.8 3326
4 50 Stranded, Class 2 10.2 27.1 30.1 32.2 35.11 38.7 4301
4 70 Stranded, Class 2 12.0 31.8 35.0 38.6 41.71 46.0 6120
4 95 Stranded, Class 2 13.55 35.6 39.0 42.5 45.69 50.4 7656
4 120 Stranded, Class 2 15.26 40.1 43.7 47.3 50.73 56.0 9364
4 150 Stranded, Class 2 16.97 44.3 48.1 51.6 55.29 61.0 11181
4 185 Stranded, Class 2 19.05 49.3 53.5 57.0 60.72 67.0 13707
4 240 Stranded, Class 2 21.6 55.9 60.5 64.0 67.9 74.9 17374
4 300 Stranded, Class 2 24.2 62.2 67.0 70.5 74.59 82.3 21002
5 1.5 Solid, Class 1 2.79 9.8 12.2 14.4 17.46 19.3 885
5 1.5 Stranded, Class 2 2.9 10.3 12.7 14.8 17.85 19.7 915
5 2.5 Solid, Class 1 3.15 10.8 13.2 15.3 18.33 20.2 993
5 2.5 Stranded, Class 2 3.31 11.5 13.9 16.0 19.01 21.0 1045
5 4 Solid, Class 1 3.61 12.1 14.4 16.6 19.59 21.6 1152
5 4 Stranded, Class 2 3.83 13.0 15.4 17.5 20.47 22.6 1227
5 6 Stranded, Class 2 4.35 14.0 16.4 18.6 21.53 23.8 1394
5 10 Stranded, Class 2 5.25 16.5 18.9 21.0 23.86 26.3 1761
5 16 Stranded, Class 2 6.25 19.2 21.6 23.7 26.48 29.2 2247
5 25 Stranded, Class 2 7.9 23.7 26.3 28.5 31.14 34.4 3159
5 35 Stranded, Class 2 8.9 26.4 29.2 31.4 34.34 37.9 3988
5 50 Stranded, Class 2 10.2 30.3 33.3 36.9 39.87 44.0 5479
5 70 Stranded, Class 2 12.0 35.2 38.6 42.1 45.3 50.0 7287
5 95 Stranded, Class 2 13.55 39.8 43.4 46.9 50.34 55.5 9228
5 120 Stranded, Class 2 15.26 44.4 48.2 51.7 55.19 60.9 11133
5 150 Stranded, Class 2 16.97 49.0 53.2 56.7 60.43 66.7 13475
5 185 Stranded, Class 2 19.05 55.0 59.4 63.0 66.93 73.8 16409
5 240 Stranded, Class 2 21.6 61.9 66.7 70.2 74.5 82.2 20691
5 300 Stranded, Class 2 24.2 69.3 74.5 78.1 82.55 91.1 25436
7 1.5 Stranded, Class 2 2.9 10.8 13.2 15.4 18.43 20.3 979
7 2.5 Stranded, Class 2 3.31 12.2 14.6 16.7 19.69 21.7 1123
10 1.5 Stranded, Class 2 2.9 13.9 16.3 18.4 21.34 23.5 1245
10 2.5 Stranded, Class 2 3.31 15.7 18.1 20.2 23.09 25.5 1464
12 1.5 Stranded, Class 2 2.9 14.4 16.8 18.9 21.82 24.1 1302
12 2.5 Stranded, Class 2 3.31 16.2 18.6 20.7 23.57 26.0 1538
14 1.5 Stranded, Class 2 2.9 15.1 17.5 19.6 22.5 24.8 1386
14 2.5 Stranded, Class 2 3.31 17.1 19.5 21.6 24.44 27.0 1657
19 1.5 Stranded, Class 2 2.9 16.8 19.2 21.3 24.15 26.6 1598
19 2.5 Stranded, Class 2 3.31 19.1 21.5 23.6 26.38 29.1 1935
24 1.5 Stranded, Class 2 2.9 19.8 22.2 24.3 27.06 29.9 1914
24 2.5 Stranded, Class 2 3.31 22.5 25.1 27.2 29.88 33.0 2419
27 1.5 Stranded, Class 2 2.9 20.2 22.6 24.7 27.45 30.3 1995
27 2.5 Stranded, Class 2 3.31 23.0 25.6 27.7 30.36 33.5 2534
30 1.5 Stranded, Class 2 2.9 21.0 23.6 25.7 28.42 31.4 2217
30 2.5 Stranded, Class 2 3.31 23.9 26.5 28.6 31.43 34.7 2728
37 1.5 Stranded, Class 2 2.9 22.8 25.4 27.5 30.17 33.3 2463
37 2.5 Stranded, Class 2 3.31 25.9 28.7 30.8 33.56 37.0 3152